Ferritin Quantitative Test

PRL Rapid Quantitative Test (Chemiluminescence Immunoassay)

PRL Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the Prolactin (PRL) concentration in human serum and plasma that contains heparin /EDTA and other anticoagulants samples, mainly used for auxiliary diagnosis of reproductive hormones diseases. 

Product Detail

Application

Prolactin (PRL) is an anterior pituitary hormone that, along with growth hormone (GH) and placental lactogens (PLs), forms a family of hormones that likely resulted from the duplication of an ancestral gene.

 

The prolactin receptor (PRLR) is also a member of a larger family, known as the cytokine class-1 receptor superfamily, which currently has more than 20 different members. PRLRs or binding sites are widely distributed throughout the body, and it is difficult to find a tissue that does not express any PRLR mRNA or protein.

 

In agreement with this broad distribution of receptors, more than 300 separate actions of PRL have been reported in various vertebrates. These actions include effects on water and salt balance, growth and development, endocrinology and metabolism, brain and behavior, reproduction, and immune regulation and protection.

 

The diverse physiological roles of PRL, mediated through its widespread receptor expression, underscore the pleiotropic nature of this anterior pituitary hormone.

 

Product Specification

Sample Volume

WB: 20μL; Serum/Plasma: 10μL

Test Time

10 mins

Measuring Range

55000 µlU/mL

Pack

20T40T100T

Storage

2~30

 

Features

Smart - Photosensitive and Luminescent Microspheres

Rapid - Whole Blood Sample Type Supported & No Centrifuge Needed

Convenient - Room Temperature Storage & Minimal sample consumption

 

Clinical significance

Evaluation of Hyperprolactinemia

Assessment of Amenorrhea and Menstrual Irregularities

Investigation of Galactorrhea

Fertility Assessment

Monitoring Treatment for Prolactinomas

Leave A Message

Please provide us with the information below, and we'll contact you as soon as possible.

Related Products
TESTO Rapid Quantitative Test (Chemiluminescence Immunoassay)
TESTO Rapid Quantitative Test (Chemiluminescence Immunoassay)
TESTO Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the Testosterone (TESTO) concentration in human serum and plasma that contains heparin /EDTA and other anticoagulants samples, mainly used for auxiliary diagnosis of reproductive hormones diseases.
LH Rapid Quantitative Test (Chemiluminescence Immunoassay)
LH Rapid Quantitative Test (Chemiluminescence Immunoassay)
LH Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the Luteinizing hormone (LH) concentration in human serum and plasma that contains heparin /EDTA and other anticoagulants samples, mainly used for auxiliary diagnosis of reproductive hormones diseases.
FSH Rapid Quantitative Test (Chemiluminescence Immunoassay)
FSH Rapid Quantitative Test (Chemiluminescence Immunoassay)
FSH Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the Follicle-stimulating hormone (FSH) concentration in human serum and plasma that contains heparin /EDTA and other anticoagulants samples, mainly used for auxiliary diagnosis of reproductive hormones diseases.
β-HCG Rapid Quantitative Test (Chemiluminescence Immunoassay
β-HCG Rapid Quantitative Test (Chemiluminescence Immunoassay
β-HCG Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the β-human chorionic gonadotropin (β-HCG) concentration in human serum, plasma that contains heparin /EDTA and other anticoagulants samples, mainly used for auxiliary diagnosis of reproductive hormones diseases.
PROG Rapid Quantitative Test (Chemiluminescence Immunoassay)
PROG Rapid Quantitative Test (Chemiluminescence Immunoassay)
PROG Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the Progesterone (PROG) concentration in human serum and plasma that contains heparin /EDTA and other anticoagulants samples, mainly used for auxiliary diagnosis of reproductive hormones diseases.
E2 Rapid Quantitative Test (Chemiluminescence Immunoassay)
E2 Rapid Quantitative Test (Chemiluminescence Immunoassay)
E2 Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the Estradiol (E2) concentration in human serum and plasma that contains heparin /EDTA and other anticoagulants and samples, mainly used for auxiliary diagnosis of reproductive hormones diseases.
AMH Rapid Quantitative Test (Chemiluminescence Immunoassay)
AMH Rapid Quantitative Test (Chemiluminescence Immunoassay)
AMH Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the Anti-Mullerian hormone (AMH) concentration in human serum and plasma that contains heparin /EDTA and other anticoagulants samples, mainly used for auxiliary diagnosis of reproductive hormones diseases.
Leave A Message

Leave A Message

    Please provide us with the information below, and we'll contact you as soon as possible.

Home

products

about

contact