Ferritin Quantitative Test

NT-proBNP Rapid Quantitative Test (Chemiluminescence Immunoassay)

NT-proBNP Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the N-terminal pro-B-type natriuretic peptideNT-proBNPconcentration in human serum, plasma that contains heparin /EDTA and other anticoagulants and venous whole blood samples, mainly used for auxiliary diagnosis of cardiac diseases.

Product Detail

Application

B-type natriuretic peptide (BNP) is a hormone produced by the human heart. N-terminal pro-B-type natriuretic peptide (NT-proBNP) is an inactive prohormone released by the same molecule that produces BNP.

 

NT-proBNP is released in response to changes in pressure within the heart. These changes may be associated with heart failure and other heart problems. Levels of NT-proBNP rise when heart failure occurs or worsens, and fall when heart failure is stable. Normally, only small amounts of NT-proBNP are found in the blood.

 

High levels of NT-proBNP may indicate that the heart is not pumping as much blood as the body needs. In most cases, patients with heart failure have higher levels of NT-proBNP than people with normal heart function. This condition is called heart failure, sometimes referred to as congestive heart failure.

 

The measurement of NT-proBNP levels is a useful diagnostic and prognostic tool for the evaluation and management of patients with suspected or known heart failure.

 

Product Specification

Sample Volume

WB: 20μL; Serum/Plasma: 10μL

Test Time

10 mins

Measuring Range

30-35000 pg/mL

Pack

20T40T100T

Storage

2~30

 

Features

1. Smart - Photosensitive and Luminescent Microspheres

2. Rapid - Whole Blood Sample Type Supported & No Centrifuge Needed

3. Convenient - Room Temperature Storage & Minimal sample consumption

 

Clinical significance

Heart Failure Diagnosis and Prognosis

Risk Stratification in Acute Coronary Syndromes

Differentiation of Dyspnea Causes

Monitoring Treatment Efficacy in Heart Failure

Screening for Asymptomatic Left Ventricular Dysfunction

Leave A Message

Please provide us with the information below, and we'll contact you as soon as possible.

Related Products
D-Dimer Rapid Quantitative Test (Chemiluminescence Immunoassay)
D-Dimer Rapid Quantitative Test (Chemiluminescence Immunoassay)
D-Dimer Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the D-Dimer concentration in human sodium citrate anticoagulant-contained plasma (1:9) and venous whole blood samples, mainly used for auxiliary diagnosis of cardiac diseases.
Myo Rapid Quantitative Test (Chemiluminescence Immunoassay)
Myo Rapid Quantitative Test (Chemiluminescence Immunoassay)
Myo Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the myoglobin (Myo) concentration in human serum, plasma that contains heparin /EDTA and other anticoagulants and venous whole blood, mainly used for auxiliary diagnosis of cardiac diseases.
hs-cTnT Rapid Quantitative Test (Chemiluminescence Immunoassay)
hs-cTnT Rapid Quantitative Test (Chemiluminescence Immunoassay)
hs-cTnT Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the high sensitivity cardiac isoform of TnT (hs-cTnT) concentration in human serum, plasma that contains heparin /EDTA and other anticoagulants and venous whole blood samples, mainly used for auxiliary diagnosis of cardiac diseases.
hs-cTnI Rapid Quantitative Test (Chemiluminescence Immunoassay)
hs-cTnI Rapid Quantitative Test (Chemiluminescence Immunoassay)
hs-cTnI Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the high sensitivity cardiac troponin I (hs-cTnI) concentration in human serum, plasma that contains heparin /EDTA and other anticoagulants and venous whole blood samples, mainly used for auxiliary diagnosis of cardiac diseases.
BNP Rapid Quantitative Test (Chemiluminescence Immunoassay)
BNP Rapid Quantitative Test (Chemiluminescence Immunoassay)
BNP Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the Brain natriuretic peptide (BNP) concentration in human plasma that contains EDTA anticoagulants and venous whole blood samples, mainly used for auxiliary diagnosis of cardiac diseases.
CK-MB Rapid Quantitative Test (Chemiluminescence Immunoassay)
CK-MB Rapid Quantitative Test (Chemiluminescence Immunoassay)
CK-MB Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the Creatine kinase-MB (CK-MB) concentration in human serum, plasma that contains heparin /EDTA and other anticoagulants and venous whole blood samples, mainly used for auxiliary diagnosis of cardiac diseases.
h-FABP Rapid Quantitative Test (Chemiluminescence Immunoassay)
h-FABP Rapid Quantitative Test (Chemiluminescence Immunoassay)
h-FABP Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the heart-type fatty acid binding protein (h-FABP) concentration in human serum, plasma that contains heparin /EDTA and other anticoagulants and venous whole blood samples, mainly used for auxiliary diagnosis of cardiac diseases.
Lp-PLA2 Rapid Quantitative Test(Chemiluminescence Immunoassay)
Lp-PLA2 Rapid Quantitative Test(Chemiluminescence Immunoassay)
Lp-PLA2 Rapid Quantitative Test(Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the lipoprotein-associated phospholipase A2 (Lp-PLA2) concentration in human serum, plasma that contains heparin /EDTA and other anticoagulants and venous whole blood samples, mainly used for auxiliary diagnosis of cardiac diseases.
Leave A Message

Leave A Message

    Please provide us with the information below, and we'll contact you as soon as possible.

Home

products

about

contact