Ferritin Quantitative Test

BNP Rapid Quantitative Test (Chemiluminescence Immunoassay)

BNP Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the Brain natriuretic peptide (BNP) concentration in human plasma that contains EDTA anticoagulants and venous whole blood samples, mainly used for auxiliary diagnosis of cardiac diseases.

Product Detail

Application

Brain natriuretic peptide (BNP) belongs to a family of protein hormones called natriuretic peptides. These peptides act on blood vessels, causing them to dilate or widen. They also work on the kidneys, stimulating the excretion of more salt and water. Additionally, the natriuretic peptides reduce the production of various hormones that can narrow blood vessels, boost heart rate, or affect fluid retention, such as adrenaline, angiotensin, and aldosterone.

 

Measuring BNP levels is helpful in determining the outlook for patients with congestive heart failure (CHF). In general, the higher the BNP level, the more severe the heart failure. BNP is also very useful in guiding the treatment of CHF. Effective therapy that reduces the backup of blood in the heart can lead to smaller heart chambers and recovery of the muscle cells, which in turn results in decreased BNP production.

 

Product Specification

Sample Volume

WB: 40μL; Serum/ Plasma: 20μL

Test Time

10 mins

Measuring Range

15-5000 pg/mL

Pack

20T40T100T

Storage

2~30

 

Features

Smart - Photosensitive and Luminescent Microspheres

Rapid - Whole Blood Sample Type Supported & No Centrifuge Needed

Convenient - Room Temperature Storage & Minimal sample consumption

 

Clinical significance

1. Heart Failure Diagnosis and Severity Assessment

2. Prognostic Indicator in Heart Failure

3. Risk Stratification in Acute Coronary Syndromes (ACS)

4. Evaluation of Dyspnea Causes in the Emergency Department

5. Monitoring Response to Heart Failure Treatment

Leave A Message

Please provide us with the information below, and we'll contact you as soon as possible.

Related Products
D-Dimer Rapid Quantitative Test (Chemiluminescence Immunoassay)
D-Dimer Rapid Quantitative Test (Chemiluminescence Immunoassay)
D-Dimer Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the D-Dimer concentration in human sodium citrate anticoagulant-contained plasma (1:9) and venous whole blood samples, mainly used for auxiliary diagnosis of cardiac diseases.
Myo Rapid Quantitative Test (Chemiluminescence Immunoassay)
Myo Rapid Quantitative Test (Chemiluminescence Immunoassay)
Myo Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the myoglobin (Myo) concentration in human serum, plasma that contains heparin /EDTA and other anticoagulants and venous whole blood, mainly used for auxiliary diagnosis of cardiac diseases.
NT-proBNP Rapid Quantitative Test (Chemiluminescence Immunoassay)
NT-proBNP Rapid Quantitative Test (Chemiluminescence Immunoassay)
NT-proBNP Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the N-terminal pro-B-type natriuretic peptide(NT-proBNP) concentration in human serum, plasma that contains heparin /EDTA and other anticoagulants and venous whole blood samples, mainly used for auxiliary diagnosis of cardiac diseases.
hs-cTnT Rapid Quantitative Test (Chemiluminescence Immunoassay)
hs-cTnT Rapid Quantitative Test (Chemiluminescence Immunoassay)
hs-cTnT Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the high sensitivity cardiac isoform of TnT (hs-cTnT) concentration in human serum, plasma that contains heparin /EDTA and other anticoagulants and venous whole blood samples, mainly used for auxiliary diagnosis of cardiac diseases.
hs-cTnI Rapid Quantitative Test (Chemiluminescence Immunoassay)
hs-cTnI Rapid Quantitative Test (Chemiluminescence Immunoassay)
hs-cTnI Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the high sensitivity cardiac troponin I (hs-cTnI) concentration in human serum, plasma that contains heparin /EDTA and other anticoagulants and venous whole blood samples, mainly used for auxiliary diagnosis of cardiac diseases.
CK-MB Rapid Quantitative Test (Chemiluminescence Immunoassay)
CK-MB Rapid Quantitative Test (Chemiluminescence Immunoassay)
CK-MB Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the Creatine kinase-MB (CK-MB) concentration in human serum, plasma that contains heparin /EDTA and other anticoagulants and venous whole blood samples, mainly used for auxiliary diagnosis of cardiac diseases.
h-FABP Rapid Quantitative Test (Chemiluminescence Immunoassay)
h-FABP Rapid Quantitative Test (Chemiluminescence Immunoassay)
h-FABP Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the heart-type fatty acid binding protein (h-FABP) concentration in human serum, plasma that contains heparin /EDTA and other anticoagulants and venous whole blood samples, mainly used for auxiliary diagnosis of cardiac diseases.
Lp-PLA2 Rapid Quantitative Test(Chemiluminescence Immunoassay)
Lp-PLA2 Rapid Quantitative Test(Chemiluminescence Immunoassay)
Lp-PLA2 Rapid Quantitative Test(Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the lipoprotein-associated phospholipase A2 (Lp-PLA2) concentration in human serum, plasma that contains heparin /EDTA and other anticoagulants and venous whole blood samples, mainly used for auxiliary diagnosis of cardiac diseases.