Ferritin Quantitative Test

hs-cTnI Rapid Quantitative Test (Chemiluminescence Immunoassay)

hs-cTnI Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the high sensitivity cardiac troponin I (hs-cTnI) concentration in human serum, plasma that contains heparin /EDTA and other anticoagulants and venous whole blood samples, mainly used for auxiliary diagnosis of cardiac diseases.

Product Detail

Application

Cardiac troponin I (cTnI) is a protein with a molecular weight of 37 kDa and is a subunit of the troponin complex involved in theregulating muscle contraction.

 

Under normal conditions, the level of peripheral blood cTnI is low. However, when acute myocardial infarction (AMI) or local ischemic injury occurs, its concentration rises rapidly due to its small molecular weight, allowing for its quick release into the human bloodstream.

 

The high sensitivity of cTnI assays makes them very effective in identifying myocardial injury, allowing them to be clinically distinguished from skeletal muscle damage caused by surgery, trauma, overexertion, or muscle disease.

 

The quantification of cTnI concentrations in human serum, plasma, and venous whole blood samples is primarily used as an aid in the diagnosis of acute myocardial infarction (AMI). The measurement of cTnI is a sensitive and specific marker of myocardial cell injury, making it a valuable tool in the evaluation and management of patients with suspected or known acute coronary syndromes.


Product Specification

Sample Volume

WB: 40μL; Serum/ Plasma: 20μL

Test Time

10 mins

Measuring Range

10-25000 pg/mL

Pack

20T40T100T

Storage

2~30

 

Features

Smart - Photosensitive and Luminescent Microspheres

Rapid - Whole Blood Sample Type Supported & No Centrifuge Needed

Convenient - Room Temperature Storage & Minimal sample consumption

 

Clinical significance

1. Early Diagnosis of Acute Myocardial Infarction (AMI)

2. Rapid Rule-In and Rule-Out of Myocardial Infarction

3. Monitoring Subclinical Cardiac Injury

4. Risk Stratification in Chronic Coronary Syndromes

5. Prognostic Marker for Cardiovascular Events

 

Leave A Message

Please provide us with the information below, and we'll contact you as soon as possible.

Related Products
D-Dimer Rapid Quantitative Test (Chemiluminescence Immunoassay)
D-Dimer Rapid Quantitative Test (Chemiluminescence Immunoassay)
D-Dimer Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the D-Dimer concentration in human sodium citrate anticoagulant-contained plasma (1:9) and venous whole blood samples, mainly used for auxiliary diagnosis of cardiac diseases.
Myo Rapid Quantitative Test (Chemiluminescence Immunoassay)
Myo Rapid Quantitative Test (Chemiluminescence Immunoassay)
Myo Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the myoglobin (Myo) concentration in human serum, plasma that contains heparin /EDTA and other anticoagulants and venous whole blood, mainly used for auxiliary diagnosis of cardiac diseases.
NT-proBNP Rapid Quantitative Test (Chemiluminescence Immunoassay)
NT-proBNP Rapid Quantitative Test (Chemiluminescence Immunoassay)
NT-proBNP Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the N-terminal pro-B-type natriuretic peptide(NT-proBNP) concentration in human serum, plasma that contains heparin /EDTA and other anticoagulants and venous whole blood samples, mainly used for auxiliary diagnosis of cardiac diseases.
hs-cTnT Rapid Quantitative Test (Chemiluminescence Immunoassay)
hs-cTnT Rapid Quantitative Test (Chemiluminescence Immunoassay)
hs-cTnT Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the high sensitivity cardiac isoform of TnT (hs-cTnT) concentration in human serum, plasma that contains heparin /EDTA and other anticoagulants and venous whole blood samples, mainly used for auxiliary diagnosis of cardiac diseases.
BNP Rapid Quantitative Test (Chemiluminescence Immunoassay)
BNP Rapid Quantitative Test (Chemiluminescence Immunoassay)
BNP Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the Brain natriuretic peptide (BNP) concentration in human plasma that contains EDTA anticoagulants and venous whole blood samples, mainly used for auxiliary diagnosis of cardiac diseases.
CK-MB Rapid Quantitative Test (Chemiluminescence Immunoassay)
CK-MB Rapid Quantitative Test (Chemiluminescence Immunoassay)
CK-MB Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the Creatine kinase-MB (CK-MB) concentration in human serum, plasma that contains heparin /EDTA and other anticoagulants and venous whole blood samples, mainly used for auxiliary diagnosis of cardiac diseases.
h-FABP Rapid Quantitative Test (Chemiluminescence Immunoassay)
h-FABP Rapid Quantitative Test (Chemiluminescence Immunoassay)
h-FABP Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the heart-type fatty acid binding protein (h-FABP) concentration in human serum, plasma that contains heparin /EDTA and other anticoagulants and venous whole blood samples, mainly used for auxiliary diagnosis of cardiac diseases.
Lp-PLA2 Rapid Quantitative Test(Chemiluminescence Immunoassay)
Lp-PLA2 Rapid Quantitative Test(Chemiluminescence Immunoassay)
Lp-PLA2 Rapid Quantitative Test(Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the lipoprotein-associated phospholipase A2 (Lp-PLA2) concentration in human serum, plasma that contains heparin /EDTA and other anticoagulants and venous whole blood samples, mainly used for auxiliary diagnosis of cardiac diseases.
Leave A Message

Leave A Message

    Please provide us with the information below, and we'll contact you as soon as possible.

Home

products

about

contact