Ferritin Quantitative Test

TT3 Rapid Quantitative Test (Chemiluminescence Immunoassay)

TT3 Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the Total Triiodothyronine (TT3) concentration in human serum, plasma that contains heparin /EDTA and other anticoagulants and venous whole blood samples, mainly used for auxiliary diagnosis of thyroid diseases.

Product Detail

Application

Triiodothyronine (T3) and thyroxine (T4) are the two primary thyroid hormones secreted by the thyroid gland. Their production and release are regulated by thyroid-stimulating hormone (TSH), which is secreted by the anterior pituitary gland. As such, serum T3 concentrations primarily reflect the functional state of the peripheral tissues, rather than the secretory capacity of the thyroid gland itself. A decrease in the conversion of T4 to T3 can result in a reduction of circulating T3 levels.

 

Thyroid dysfunction can lead to either an overproduction (hyperthyroidism) or underproduction (hypothyroidism) of T3 and T4. Additionally, thyroid function can be affected if the pituitary gland or hypothalamus is dysfunctional, due to the direct influence of TSH.

 

The measurement of blood T3 levels can be used as an aid in the diagnosis of various thyroid disorders, as well as for monitoring the effectiveness of treatment in related patients. By assessing T3 concentrations, clinicians can gain valuable insights into the underlying thyroid hormone dynamics, which is crucial for the effective management of thyroid diseases.

 

Product Specification

Sample Volume

WB: 40μL; Serum/Plasma: 20μL

Test Time

15 mins

Measuring Range

0.195-6.51 ng/mL

Pack

20T40T100T

Storage

2~30

 

Features

Smart - Photosensitive and Luminescent Microspheres

Rapid - Whole Blood Sample Type Supported & No Centrifuge Needed

Convenient - Room Temperature Storage & Minimal sample consumption

 

Clinical significance

1. Thyroid Function Assessment

2. Diagnosis and Monitoring of Hyperthyroidism

3. Assessment of Thyroid Medication Dosage

4. Evaluation of Thyroid Disorders in Pregnancy

5. Assessment of Thyroid Nodule Function

Leave A Message

Please provide us with the information below, and we'll contact you as soon as possible.

Related Products
TSH Rapid Quantitative Test(Chemiluminescence Immunoassay)
TSH Rapid Quantitative Test(Chemiluminescence Immunoassay)
TSH Rapid Quantitative Test(Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the thyroid stimulating hormone concentration in human serum, plasma that contains heparin /EDTA and other anticoagulants and venous whole blood samples, mainly used for auxiliary diagnosis of thyroid diseases.
FT4 Rapid Quantitative Test (Chemiluminescence Immunoassay)
FT4 Rapid Quantitative Test (Chemiluminescence Immunoassay)
FT4 Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the Free thyroxine 4 (FT4) concentration in human serum, plasma that contains heparin /EDTA and other anticoagulants and venous whole blood samples, mainly used for auxiliary diagnosis of thyroid diseases.
TT4 Rapid Quantitative Test (Chemiluminescence Immunoassay)
TT4 Rapid Quantitative Test (Chemiluminescence Immunoassay)
TT4 Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the total thyroxine 4 (TT4) concentration in human serum, plasma that contains heparin /EDTA and other anticoagulants and venous whole blood samples, mainly used for auxiliary diagnosis of thyroid diseases.
FT3 Rapid Quantitative Test (Chemiluminescence Immunoassay)
FT3 Rapid Quantitative Test (Chemiluminescence Immunoassay)
FT3 Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the Free triiodothyronine 3 (FT3) concentration in human serum, plasma that contains heparin /EDTA and other anticoagulants and venous whole blood samples, mainly used for auxiliary diagnosis of thyroid diseases.
 Monkeypox Virus ( Real-time PCR ) test kit
Detection Kit for Monkeypox Virus ( Real-time PCR )
Detection Kit for Monkeypox Virus ( Real-time PCR ) is designed for the qualitative detection of Monkeypox Virus (MPV) DNA extracted from skin, fluid, or crusts collected directly from skin lesions. It's based on real-time PCR technology, the primers and probes target specific sequences of MPV, and do not react with nucleic acids of other pathogens.
Biotime D Dimer Chronic heart failure
D-Dimer Rapid Quantitative Test
Biotime D-Dimer test kit (Analyzer + Test cassette) is performed to help rule out Deep Vein Thrombosis (DVT), Pulmonary Embolism (PE) and stroke. It can perform the test accurately and rapidly within 3 min with the Biotime immunofluorescence analyzer.
 TT3 Rapid Quantitative Test
TT3 Rapid Quantitative Test
TT3 is the main hormone that thyroid hormone does to various target organs. The serum TT3 concentration reflects the thyroid gland’s ability to function better than the thyroid gland. TT3 is an important indicator of early hyperthyroidism and the monitoring of recurrent hyperthyroidism and pseudo thyrotoxicosis.
Chemiluminescence Immunoassay
CLi-1600
CLi-1600 semi-automated device which quantifies biomarkers for thyroid disease, inflammation, cardiac diseases, fertility, diabetes, bone metabolism, anemia, and health check by analyzing human serum, plasma and whole blood.
Leave A Message

Leave A Message

    Please provide us with the information below, and we'll contact you as soon as possible.