Ferritin Quantitative Test

IL-6 Rapid Quantitative Test (Chemiluminescence Immunoassay)

IL-6 Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the Interleukin-6 (IL-6) concentration in human serum, plasma that contains heparin /EDTA and other anticoagulants and venous whole blood samples, mainly used for auxiliary diagnosis of inflammation diseases.

Product Detail

Application

Interleukin-6 (IL-6) is a pleiotropic cytokine involved in the physiology of virtually every organ system. Recent studies have demonstrated that IL-6 plays a crucial role in regulating the balance between IL-17-producing T helper 17 (Th17) cells and regulatory T (Treg) cells.

 

These two T-cell subsets play prominent and opposing roles in immune functions. Th17 cells are key players in the pathogenesis of autoimmune diseases and provide protection against certain bacterial infections, while Treg cells function to restrain excessive effector T-cell responses.

 

IL-6 induces the development of Th17 cells from naïve T cells, in conjunction with transforming growth factor-beta (TGF-β). In contrast, IL-6 inhibits the TGF-β-induced differentiation of Treg cells. This modulation of the Th17/Treg balance by IL-6 is an important mechanism underlying its involvement in both autoimmunity and host defense.

 

Product Specification

Sample Volume

WB: 40μL; Serum/Plasma: 20μL

Test Time

10 mins

Measuring Range

5-5000 pg/mL

Pack

20T、40T、100T

Storage

2~30℃

 

Features

Smart - Photosensitive and Luminescent Microspheres

Rapid - Whole Blood Sample Type Supported & No Centrifuge Needed

Convenient - Room Temperature Storage & Minimal sample consumption

 

Clinical significance

Rheumatoid Arthritis and Autoimmune Diseases

Cytokine Release Syndrome (CRS) Assessment

Sepsis and Inflammatory Response

Assessment of Inflammatory Bowel Disease (IBD)

Cardiovascular Risk Assessment

Leave A Message

Please provide us with the information below, and we'll contact you as soon as possible.

Related Products
CRP Rapid Quantitative Test (Chemiluminescence Immunoassay)
CRP Rapid Quantitative Test (Chemiluminescence Immunoassay)
CRP Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the C-reactive proteins (CRP) concentration in human serum, plasma and vein whole blood specimens.
PCT Rapid Quantitative Test (Chemiluminescence Immunoassay)
PCT Rapid Quantitative Test (Chemiluminescence Immunoassay)
PCT Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the Procalcitonin concentration in human serum, plasma that contains heparin /EDTA and other anticoagulants and venous whole blood samples, mainly used for auxiliary diagnosis of inflammation diseases.
SAA Rapid Quantitative Test (Chemiluminescence Immunoassay)
SAA Rapid Quantitative Test (Chemiluminescence Immunoassay)
SAA Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the Serum amyloid A (SAA) concentration in human serum, plasma that contains heparin /EDTA and other anticoagulants and venous whole blood samples, mainly used for auxiliary diagnosis of inflammation diseases.
HBP Rapid Quantitative Test (Chemiluminescence Immunoassay)
HBP Rapid Quantitative Test (Chemiluminescence Immunoassay)
HBP Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the Heparin binding protein (HBP) concentration in human plasma that contains Sodium Citrate samples, mainly used for auxiliary diagnosis of inflammation diseases.
Lp-PLA2 Rapid Quantitative Test(Chemiluminescence Immunoassay)
Lp-PLA2 Rapid Quantitative Test(Chemiluminescence Immunoassay)
Lp-PLA2 Rapid Quantitative Test(Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the lipoprotein-associated phospholipase A2 (Lp-PLA2) concentration in human serum, plasma that contains heparin /EDTA and other anticoagulants and venous whole blood samples, mainly used for auxiliary diagnosis of cardiac diseases.
Biotime HLC-100 Fully Automated HbA1c Analyzer
HLC-100 Fully Automated HbA1c Analyzer
Biotime’s HLC-100 Fully Automated HbA1c Analyzer provides a prompt, reliable solution for diabetes diagnosis. It utilizes the high performance liquid chromatography (HPLC) analytical technique, a gold standard that helps detect glycosylated hemoglobin (HbA1c) with superior precision. Its capability to measure HbA1c, HbF, and other hemoglobin fragments enables clinicians to make quick, accurate diagnoses, thus facilitating timely treatment for the patient.
HbA1c Analyzer
HLC-100 Fully Automated HbA1c Analyzer
Biotime’s HLC-100 Fully Automated HbA1c Analyzer provides a prompt, reliable solution for diabetes diagnosis. It utilizes the high performance liquid chromatography (HPLC) analytical technique, a gold standard that helps detect glycosylated hemoglobin (HbA1c) with superior precision. Its capability to measure HbA1c, HbF, and other hemoglobin fragments enables clinicians to make quick, accurate diagnoses, thus facilitating timely treatment for the patient.
Biotime CRP Rapid Quantitative Test
CRP Rapid Quantitative Test
The C-reactive protein(CRP) is synthesized by the liver in response to interleukin-6 and is well known as one of the classical acute-phase reactants. It is used as a marker of inflammation and cardiovascular diseases(C-VD). Biotime CRP test includes hs-CRP and normal CRP test parameters which has wider test range.