Ferritin Quantitative Test

IL-6 Rapid Quantitative Test (Chemiluminescence Immunoassay)

IL-6 Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the Interleukin-6 (IL-6) concentration in human serum, plasma that contains heparin /EDTA and other anticoagulants and venous whole blood samples, mainly used for auxiliary diagnosis of inflammation diseases.

Product Detail

Application

Interleukin-6 (IL-6) is a pleiotropic cytokine involved in the physiology of virtually every organ system. Recent studies have demonstrated that IL-6 plays a crucial role in regulating the balance between IL-17-producing T helper 17 (Th17) cells and regulatory T (Treg) cells.

 

These two T-cell subsets play prominent and opposing roles in immune functions. Th17 cells are key players in the pathogenesis of autoimmune diseases and provide protection against certain bacterial infections, while Treg cells function to restrain excessive effector T-cell responses.

 

IL-6 induces the development of Th17 cells from naïve T cells, in conjunction with transforming growth factor-beta (TGF-β). In contrast, IL-6 inhibits the TGF-β-induced differentiation of Treg cells. This modulation of the Th17/Treg balance by IL-6 is an important mechanism underlying its involvement in both autoimmunity and host defense.

 

Product Specification

Sample Volume

WB: 40μL; Serum/Plasma: 20μL

Test Time

10 mins

Measuring Range

5-5000 pg/mL

Pack

20T、40T、100T

Storage

2~30℃

 

Features

Smart - Photosensitive and Luminescent Microspheres

Rapid - Whole Blood Sample Type Supported & No Centrifuge Needed

Convenient - Room Temperature Storage & Minimal sample consumption

 

Clinical significance

Rheumatoid Arthritis and Autoimmune Diseases

Cytokine Release Syndrome (CRS) Assessment

Sepsis and Inflammatory Response

Assessment of Inflammatory Bowel Disease (IBD)

Cardiovascular Risk Assessment

Leave A Message

Please provide us with the information below, and we'll contact you as soon as possible.

Related Products
CRP Rapid Quantitative Test (Chemiluminescence Immunoassay)
CRP Rapid Quantitative Test (Chemiluminescence Immunoassay)
CRP Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the C-reactive proteins (CRP) concentration in human serum, plasma and vein whole blood specimens.
PCT Rapid Quantitative Test (Chemiluminescence Immunoassay)
PCT Rapid Quantitative Test (Chemiluminescence Immunoassay)
PCT Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the Procalcitonin concentration in human serum, plasma that contains heparin /EDTA and other anticoagulants and venous whole blood samples, mainly used for auxiliary diagnosis of inflammation diseases.
SAA Rapid Quantitative Test (Chemiluminescence Immunoassay)
SAA Rapid Quantitative Test (Chemiluminescence Immunoassay)
SAA Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the Serum amyloid A (SAA) concentration in human serum, plasma that contains heparin /EDTA and other anticoagulants and venous whole blood samples, mainly used for auxiliary diagnosis of inflammation diseases.
HBP Rapid Quantitative Test (Chemiluminescence Immunoassay)
HBP Rapid Quantitative Test (Chemiluminescence Immunoassay)
HBP Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the Heparin binding protein (HBP) concentration in human plasma that contains Sodium Citrate samples, mainly used for auxiliary diagnosis of inflammation diseases.
Toxoplasma IgG/IgM Rapid Test (Fluorescence Immunoassay)
Toxoplasma IgG/IgM Rapid Test (Fluorescence Immunoassay)
TheToxoplasma IgG/IgM Rapid Test is an in vitro immunoassay for the in vitro qualitative determination of IgG and IgM class antibodies toToxoplasma gondii in human serum.IgG results with this assay are used to indicate past or recent infection withToxoplasma gondii. IgM results obtained with this assay are used as an aid in the diagnosis of acute or recentToxoplasma gondii infections. Toxoplasma IgM test shall not be used for prenatal screening of asymptomatic people, and the test results of this reagent shall not be used alone as the basis for termination of pregnancy. -Fluorescent immunoassay -Toxoplasma gondii infection -For in vitro diagnostic use only. For professional use only.
E2 Rapid Quantitative Test (Chemiluminescence Immunoassay)
E2 Rapid Quantitative Test (Chemiluminescence Immunoassay)
E2 Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the Estradiol (E2) concentration in human serum and plasma that contains heparin /EDTA and other anticoagulants and samples, mainly used for auxiliary diagnosis of reproductive hormones diseases.
biotime PGI Rapid Quantitative Test
PGI Rapid Quantitative Test
Human Pepsinogens are aspartic proteases produced in the gastric mucosa and secreted into the gastric lumen that play a major role in the digestion of proteins after activation of acidic pH. It is synthesized as isoymogens and is classified into two groups (Pepsinogen I and Pepsinogen II).
PCT Rapid Quantitative Test (Chemiluminescence Immunoassay)
PCT Rapid Quantitative Test (Chemiluminescence Immunoassay)
PCT Rapid Quantitative Test (Chemiluminescence Immunoassay) is used for in vitro quantitative detection of the Procalcitonin concentration in human serum, plasma that contains heparin /EDTA and other anticoagulants and venous whole blood samples, mainly used for auxiliary diagnosis of inflammation diseases.
Leave A Message

Leave A Message

    Please provide us with the information below, and we'll contact you as soon as possible.

Home

products

about

contact